run_design_verification#
module wntr.extensions.design_verification.runner
- run_design_verification(wn, scenario, *, design=None, simulator='WNTRSimulator', minimum_pressure_m=15.0, maximum_velocity_mps=2.5, required_compliance_pct=100.0, pressure_tolerance_m=0.0, velocity_tolerance_mps=0.0)[source]#
Run one hydraulic design-verification assessment.
The original network is protected from modification. Pipe-diameter changes and hydraulic simulation-option changes are applied to independent copies.
- Parameters:
wn (WaterNetworkModel) – Original WNTR water-distribution network model.
scenario (HydraulicScenario) – WNTR time and hydraulic simulation options to assess.
design (PipeDesign or None, optional) – Optional pipe-diameter design. If omitted, the unchanged baseline network is assessed.
simulator (str, optional) – Hydraulic simulation engine. Accepted values are
WNTRSimulatorandEpanetSimulator.minimum_pressure_m (float, optional) – Minimum acceptable junction pressure in metres.
maximum_velocity_mps (float, optional) – Maximum acceptable absolute pipe velocity in metres per second.
required_compliance_pct (float, optional) – Required percentage of assessed node-time and pipe-time values satisfying each constraint.
pressure_tolerance_m (float, optional) – Non-negative numerical tolerance applied below the minimum pressure limit. The default of zero preserves strict comparison behaviour.
velocity_tolerance_mps (float, optional) – Non-negative numerical tolerance applied above the maximum absolute velocity limit. The default of zero preserves strict comparison behaviour.
- Returns:
verification (VerificationResult) – Structured pressure, velocity, pump and overall feasibility result.
hydraulic_results (Any) – Raw WNTR hydraulic simulation results.
audit (dict) – Record of the applied design, scenario, simulator and assessed components.
- Return type: